Input
Input range: 90 - 264 Vac; 120 - 300 Vdc
Frequency: 47 - 63 Hz
Inrush current: 50 A max., cold start @ 25°C
Output
Maximum power: 125 W for convection (100 W for LPS202-M); 250 W (200 W for LPS202-M) with 30CFM forced air
Adjustment range: ± 10% minimum on the main outputs
Hold-up time: 16 ms @ 250 W load, 120 Vac input
Environmental Specifications
Operating temperature: 0°C to 50°C ambient derate each output as 2.5% per degree from 50° to 70°C. -20°C start up
Storage temperature: -40 °C to +85 °C
Humidity: Operating; non-condensing 10% to 95% RH
Function: EMI/RFI, power factor, safety ground leakage curent, fan output, overload protection, overvoltage protection; power failure, remote sense
Ordering Information:
Output Voltage: 5 V
Minimum Load: 0 V
Maximum Load with Convection Cooling: 20 A
Maximum Load with 30CFM Forced Air: 40 A
Peak Load: 44 A
Regulation: ± 2%
Ripple P/P (PARD): 50 mV