Input
Input range: 85 - 264 Vac; 120 - 300 Vdc
Frequency: 47 - 440 Hz
Inrush current:
< 18 A peak @ 115 Vac;
< 36 A peak @ 230 Vac, cold start @ 25°C
Input current: 1 A max. (RMS) @ 115 Vac
Efficiency: 70% typical at full load (60% for LPT41)
EMI: FCC Class B conducted; CISPR 22 Class B conducted EN55022 Class B conducted; VDE 0878 PT3 Class B conducted
Safety ground leakage current: < 0.5 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power:
40 W for convection (LPT41, 25 W);
55 W with 30CFM forced air (LPT41, 41 W)
Cross regulation: ±2% on output 1; ±5% on outputs 2, 3
Adjustment range: -5, +10% minimum
Hold-up time: 20 ms @ 40 W load, 115 Vac nominal line
Overload protection: Short circuit protection on all outputs. Case overload protected @ 110% to 145% above peak rating
Overvoltage protection: 5.7 to 6.7 Vdc on the main outputLPT41: 3.6 to 4.6 Vdc
Remote sense: Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Environmental Specifications
Operating temperature: 0°C to 50°C ambient derate each output at 2.5% per degree from 50°C to 70°C, -20°C start up.
Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing 5% to 95%
Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40°C to 85°C
Temperature coefficient: ±0.4% per °C
MTBF demonstrated: > 550.000 hours at full load and 25°C ambient conditions
Ordering Information
Output: Tripple
1.
Output Voltage: +5 V
Minimum Load: 0.4 A
Maximum Load with Convection Cooling: 4 A
Maximum Loadwith 30CFM Forced Air: 5 A
Peak Load: 7 A
Regulation: ±2%
Ripple P/P(PARD): 50 mV
2.
Output Voltage: +12 V
Minimum Load: 0.2 A
Maximum Load with Convection Cooling: 2 A
Maximum Loadwith 30CFM Forced Air: 2.5 A
Peak Load: 4 A
Regulation: ±5%
Ripple P/P(PARD): 120 mV
3.
Output Voltage: -5 V
Minimum Load: 0 A
Maximum Load with Convection Cooling: 0.5 A
Maximum Loadwith 30CFM Forced Air: 0.7 A
Peak Load: 1 A
Regulation: ±5%
Ripple P/P(PARD): 50 mV