Frequency Range

• 4024CA:9kHz~9GHz

• Frequency Resolution:1Hz

Frequency Reference

• Frequency: 10MHz

• Aging Rate: ±0.5ppm/Year

• Initial Frequency Accuracy: ±0.3ppm

• Temperature Stability:±0.1ppm(-10~50℃, Comparative to 25℃)

Sweep Time

• Range: 10μs~6000s (Zero Span)

• Accuracy: ±2.00% (Zero Span)

Frequency Readout Accuracy: ±(Frequency Readout× frequency Reference +2%× Span +10%× Resolution Bandwidth)

Frequency Span

• Range: 100Hz~9GHz or 0Hz

• Accuracy: ±2.0%

Resolution Bandwidth: 1Hz~10MHz (1-3 Times of Stepping), 20MHz

Video Bandwidth: 1Hz~10MHz (1-3 Times of Stepping), 20MHz

SSB Phase Noise (Carrier 1GHz)

• ≤-108dBc/Hz@ Frequency Offset 10kHz

• ≤-110dBc/Hz@ Frequency Offset 100kHz

• ≤-118dBc/Hz@ Frequency Offset 1MHz

• ≤-129dBc/Hz@ Frequency Offset 10MHz

Displayed Average Noise Level (input port is connected with a 50Ω load, 0dB input attenuation, average detection, logarithm of video type, RBW normalized to 1Hz, tracking source off, 20℃~30℃)

• Pre-amplifier Off:

≤-140dBm(2MHz~3GHz)

≤-138dBm(3GHz~9GHz)

• Pre-amplifier On:

≤-160dBm(2MHz~3GHz)

≤-157dBm(3GHz~9GHz)

Residual Response (exceptional frequency: 3.15GHz):

• Pre-amplifier Off:

≤-82dBm(10MHz~9GHz)

• Pre-amplifier On:

≤-95dBm(10MHz~9GHz)

Second Harmonic Distortion (0dB attenuation, -30dBm input signal)

• 50MHz~2GHz: <-65dBc

• 2GHz~4.5GHz: <-70dBc

TOI(-15dBm two-tone signal, 100kHz span, pre-amplifier off)

• 50MHz~5.2GHz ≥+10dBm

• 5.2GHz~9GHz ≥+12dBm

Absolute Amplitude Accuracy (input signal 0dBm~-50dBm, all settings are automatic couplings, 20℃~30℃, 30 minutes of preheating) : ±1.3dB (10MHz~9GHz)

Input Attenuator: Attenuation Range: 0dB~30dB, 5dB Steps

Maximum Continuous Input

+27dBm Peak Typical(≥10dB Attenuation)

+20dBm Peak Typical(<10dB Attenuation)

+10dBm Peak Typical(Pre-amp On)

Reference Level

• Range: -150dBm~+30dBm

• Conversion Uncertainty: ±1.20dB

Dimension

• 314mm (W)×218mm (H)×91mm (D) (Excluding Handle, Stand)

• 338mm(W)×218mm (H)×100mm (D) (Including Handle, Stand)

Weight: ≤4.6kg

Working Temperature: -10℃~+50℃ (the battery operation temperature is 0℃~+45℃)

Storage Temperature: -40℃~+70℃ (the battery storage temperature is -20℃~+60℃)

Electromagnetic Compatibility: Conforms to GJB3947A-2009 3.9.1 Requirements

Power Supply

• AC power adapter: input 100 to 240VAC, 50/60Hz Output 15VDC, 4A

• Lithium-ion battery: 10.8V

Battery operation time: 2h (typical)

Power Consumption: ≤40W

Test Interface: RF input: Type-N Connector(female)

Other Interfaces

• 10MHz Reference Input/Output: BNC (female) Connector

• External Triggering Input: BNC (female) Connector

• IF Output: BNC (female) Connector

• GPS Antenna Input: BNC (female) Connector