Chamber Design:

Internal Volume (L): 600

Internal Dimensions (cm): 100x100x60

External Dimensions (cm): 130x254x195

Temperature Test Parameters:

Temperature Range (°C): -40°C~+160°C

Heating Rate(°C/min): Raise from 25 ℃ to 120 ℃ for 60 minutes, with an average of the entire process (no load at atmospheric pressure)

Cooling Rate(°C/min): Reduce from 25 ℃ to -40 ℃ for 60 minutes, with an average of the entire process (no load at atmospheric pressure)

Excessive Temperature Rise And Fall: ≤± 2 ℃, no overshoot within the allowable temperature deviation range according to GB/T5170

Temperature Fluctuation(°C): <1.0(Atmospheric No-load)

TemperatureUniformity(°C): ≤ 2.0 (Atmospheric -40~+110 ℃ Range/No-load)

Temperature Deviation(°C): Deviation ± 2 ℃ when<100 ℃ to -40 ℃ (atmospheric no-load) Deviation ± 3 ℃ when ≥ 100 ℃

Pressure Test Parameters:

Pressure Range(KPa): 1KPa ~atmospheric pressure

Air Pressure Deviation(KPa): ≤± 2kpa (≥ 40kpa), ≤± 5kpa (5 to 40kpa)

Low Pressure Indication Error(KPa): ≤± 2kpa (≥ 40kpa), ≤± 5kpa (5 to 40kpa)

Air Pressure Change Rate(KPa/Min): Pressure change rate ≥ 3kpa/min (entire pressure range, with load) Note: Pressure reduction rate ≥ 2500ft/min (normal pressure~25kPa, with load)

Voltage Reduction Time(Min): Less than 20 minutes at atmospheric pressure~5KPa

Pressure Recovery Speed(KPa/Min): Less than 10KPa per minute

Comprehensive Parameters:

Comprehensive Inspection Of Temperature Deviation: ≤± 3 ℃ (0~100 ℃), ≤± 5 ℃ (100-160 ℃), ≤± 2 ℃ (normal pressure~50kpa/0~40 ℃)

Comprehensive Inspection Of Low-pressure Deviation: ≤± 2kpa (≥ 40kpa), ≤± 5% kpa (5-40kpa)

Comprehensive Inspection Of Temperature Fluctuation: ≤1.0℃

Comprehensive Inspection Of Temperature Uniformity: ≤± 3 ℃ (0~100 ℃), ≤± 5 ℃ (100-160 ℃), ≤± 2 ℃ (normal pressure~50kpa/0~~50 ℃)

Comprehensive Inspection Of Temperature Indication Error: ≤± 3 ℃ (0~100 ℃), ≤± 5 ℃ (100-160 ℃), ≤± 2 ℃ (normal pressure~50kpa/0~40 ℃)

Comprehensive Inspection Of Low-pressure Indication Error: ≤± 2kpa (≥ 40kpa), ≤± 5% kpa (5-40kpa)

Comprehensive Inspection Of Low-pressure Change Rate: Pressure reduction rate ≥ 2500ft/min (atmospheric pressure~25kPa, with load)

Power Supply And Connection:

Rated Voltage(V/HZ): AC380V 50HZ(Can be adapted to different national voltage requirements)

Control Mode: PID+SSR

Environmental Temperature/Humidity For Use: A air-cooled (ambient temperature: 5 ℃~28 ℃)/W water-cooled (water temperature: 10 ℃~28 ℃, water pressure: 0.25~0.4MPa)

System Components:

Material Science:

Shell Material: Double sided spray painted 1.5mm galvanized color steel plate

Inner Liner Material: SUS # 304 stainless steel plate

Thermal Insulation Material: Rigid polyurethane foam

Refrigeration System:

Cooling Method: Butterfly valve compression refrigeration

Compressor: Emerson Valley Wheel Fully Dense Vortex Compressor

Refrigerant: Non fluorinated environmentally friendly refrigerant HFC R404A R23

Heating System: Nickel chromium wire heater

Circulating Fan: Centrifugal fan

Door Observation Window: The single door is equipped with a 3-layer vacuum glass observation window for heat and sweat prevention; Door frame electric heating (automatic adjustment) anti frost and anti condensation device

Temperature Sensor: Platinum resistance PT100

Temperature Controller: High precision resistive touch screen, can be controlled by a USB external mouse; Historical curve record, PID+SSR/SCR automatic bidirectional synchronous output

Noise(dB(A)): Below 75dB from 1 meter away

Enclosure: Stainless steel test rack with 2 layers; User manual, technical data

Features

Wide Temperature Range: Operates from -70°C to 160°C, covering extensive testing needs.

Wide Pressure Range: Simulates low-pressure conditions with a pressure range from 1KPa (approximately 10 mbar) to standard atmospheric pressure, ideal for testing high-altitude and space environments.

Temperature and Pressure Control: Offers precise control over both temperature and pressure to create stable, repeatable testing conditions for a variety of applications.

Built-in Safety Features: Includes safety mechanisms such as pressure relief valves and automatic shutdown to protect both the chamber and the products being tested.

Real-Time Monitoring: Equipped with advanced monitoring and data logging systems to track pressure, temperature, and humidity throughout the test cycle, ensuring compliance with industry standards.

High-Quality Construction: Designed with durable, high-performance materials to withstand extreme conditions and ensure reliable operation over time.

Customizable Testing Conditions: Provides the flexibility to simulate a variety of environmental conditions, meeting the needs of industries that require non-standard or specialized testing.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts