For full functionality of this site it is necessary to enable JavaScript.
EMINKH.COM
0
Product image

PRODIGIT 3356G Compact High Power DC Electronic Load (6000W, 600A/150V)

Model3356G
OriginTaiwan
Warranty12 months
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Power: 0~6000W / 0~9000W max

Current: 0~600A / 0~900A max

Voltage: 0~150V

Min.Operatting Voltage: 0.7V @ 600A

Protections

Over Power Protection (OPP): 105%

Over Current Protection (OCP): 104%

Over Voltage Protection (OVP): 105%

Over Temp Protection (OTP): 90℃ ± 5℃

Constant Current Mode

Range: 0~60A / 0~600A

Resolution: 0.00096A / 0.0096A

Accuracy: ± 0.05% of (Setting + Range)

Constant Resistance Mode

Range: 0.25~15000Ω / 0.0012~0.25Ω

Resolution: 0.000067S / 0.000004167Ω

Accuracy: ± 0.2% of (Setting + Range)

Constant Voltage Mode

Range: 0~15V / 0~150V

Resolution: 0.0025V / 0.025V

Accuracy: ± 0.05% of (Setting + Range)

Constant Power Mode

Range: 0~600W / 0~6000W

Resolution: 0.0096W / 0.096W

Accuracy: ± 0.1% of (Setting + Range)

Constant Voltage Mode + Constant Current Mode

Range: 150V / 600A

Resolution: 0.0025V / 0.0096A

Accuracy: ± 1.0% of (Setting + Range)

Constant Voltage Mode + Constant Power Mode

Range: 150V / 6000W

Resolution: 0.0025V / 0.1W

Accuracy: ± 1.0% of (Setting + Range)

Turbo mode OFF / ON

Short/OCP/OPP Test Function

Maximum Current: 600A / 900A

Meas. Accuracy: ± 1.0% of (Reading + Range)

Short time: 100~10000mS;Continuous / 100~10000mS

Meas. Accuracy: NA / NA

OCP Time (Tstep): 100mS / 200mS

Meas. Accuracy: NA / NA

OPP Time (Tstep): 100mS / 200mS

Meas. Accuracy: NA /NA

BMS Test Mode OFF/ON (Turbor mode OFF) / OFF/ON (Turbor mode ON)

Short time: 100mS~10S/0.05~10mS / 100~1000mS/0.05~10mS

Meas. Accuracy: NA/±0.005mS / NA/±0.005mS

OCP Time (Tstep): 100mS/0.05~10mS;11~1000mS / 20mS/0.05~10mS;11~1000mS

Meas. Accuracy: NA/±0.005mS;±0.2mS / NA/±0.005mS;±0.2mS

Surge Test Mode

Surge current: 0~900A

Normal current: 0~450A

Surge Time: 10~2000ms

Surge Step: 1~5

MPPT Mode

Algorithm: P&O

Load mode: CV

P&O interval: 1000-6000mS

Resolution: 1000mS

Dynamic Mode

Timing:

Thigh & Tlow: 0.010~9.999/99.99/999.9/mS

Resolution: 0.0001/0.01/0.1/1mS

Accuracy: 1/10/100/1000 uS+50ppm

Slew rate: 0.0384~2.400A/uS / 0.3840~24.000A/uS

Resolution: 0.00096A/uS / 0.0096A/uS

Min. Rise Time: 25uS (Typ.)

Current:

Range: 0~60A / 60~600A

Resolution: 0.00096A / 0.0096A

Measurement

Voltage Read Back

Range (5 Digital): 0~15V / 15~150v

Resolution: 0.00025V / 0.0025V

Accuracy: ± 0.025% of (Reading + Range)

Current Read Back

Range (5 Digital): 0~60A / 60~600A

Resolution: 0.00096A / 0.0096A

Accuracy: ± 0.05% of (Reading + Range)

Power Read Back

Range (5 Digital): 6000W

Accuracy: ± 0.06% of (Reading + Range)

General

Typical Short Resistance: 0.0012Ω

Maximum Short Current: 600A

Load ON Voltage: 0.25~62.5V

Load OFF Voltage: 0~62.5V

Power Consumption: 550VA

Dimension (HxWxD): 177mm x 440mm x 745mm

Weight: 28kg

Temperature: 0~40℃

Safety & EMC: CE

Option card: GPIB, RS232, USB, LAN are option, prices are same as 331XF

Datasheet

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts