For full functionality of this site it is necessary to enable JavaScript.
EMINKH.COM
0
Product image

PRODIGIT 3366G Compact High Power DC Electronic Load (6000W, 420A/600V)

Model3366G
OriginTaiwan
Warranty12 months
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Power: 0~6000W / 0~9000W max

Current: 0~420A / 0~630A max

Voltage: 0~600V

Min.Operatting Voltage: 10V @ 420A

Protections

Over Power Protection (OPP): 105%

Over Current Protection (OCP): 104%

Over Voltage Protection (OVP): 105%

Over Temp Protection (OTP): 90℃ ± 5℃

Constant Current Mode

Range: 0~42A / 0~420A

Resolution: 0.000672A / 0.00672A

Accuracy: ± 0.05% of (Setting + Range)

Constant Resistance Mode

Range: 1.4825~85712Ω / 0.02384~1.4285Ω

Resolution: 0.000012S / 0.000024Ω

Accuracy: ± 0.2% of (Setting + Range)

Constant Voltage Mode

Range: 0~60V / 0~600V

Resolution: 0.001V / 0.01V

Accuracy: ± 0.05% of (Setting + Range)

Constant Power Mode

Range: 0~600W / 0~6000W

Resolution: 0.0096W / 0.096W

Accuracy: ± 0.1% of (Setting + Range)

Constant Voltage Mode + Constant Current Mode

Range: 600V / 420A

Resolution: 0.01V / 0.00672A

Accuracy: ± 1.0% of (Setting + Range)

Constant Voltage Mode + Constant Power Mode

Range: 600V / 6000W

Resolution: 0.0096V / 0.096W

Accuracy: ± 1.0% of (Setting + Range)

Turbo mode OFF / ON

Short/OCP/OPP Test Function

Maximum Current: 420A / 630A

Meas. Accuracy: ± 1.0% of (Reading + Range)

Short time: 100~10000mS;Continuous / 100~20000mS

Meas. Accuracy: NA / NA

OCP Time (Tstep): 100mS / 20mS

Meas. Accuracy: NA / NA

OPP Time (Tstep): 100mS / 20mS

Meas. Accuracy: NA /NA

BMS Test Mode OFF/ON (Turbor mode OFF) / OFF/ON (Turbor mode ON)

Short time: 100mS~10S/0.05~10mS / 100~1000mS/0.05~10mS

Meas. Accuracy: NA/±0.005mS / NA/±0.005mS

OCP Time (Tstep): 100mS/0.05~10mS;11~1000mS / 20mS/0.05~10mS;11~1000mS

Meas. Accuracy: NA/±0.005mS;±0.2mS / NA/±0.005mS;±0.2mS

Surge Test Mode

Surge current: 0~630A

Normal current: 0~315A

Surge Time: 10~2000ms

Surge Step: 1~5

MPPT Mode

Algorithm: P&O

Load mode: CV

P&O interval: 1000-60000mS

Resolution: 1000mS

Dynamic Mode

Timing:

Thigh & Tlow: 0.010~9.999/99.99/999.9/mS

Resolution: 0.0001/0.01/0.1/1mS

Accuracy: 1/10/100/1000 uS+50ppm

Slew rate: 0.02688~1.680A/uS / 0.2688~16.800A/uS

Resolution: 0.00672A/uS / 0.0672A/uS

Min. Rise Time: 25uS (Typ.)

Current:

Range: 0~42A / 42~420A

Resolution: 0.00067A / 0.0067A

Measurement

Voltage Read Back

Range (5 Digital): 0~60V / 60~600v

Resolution: 0.00100V / 0.0100V

Accuracy: ± 0.025% of (Reading + Range)

Current Read Back

Range (5 Digital): 0~42A / 42~420A

Resolution: 0.000672A / 0.00672A

Accuracy: ± 0.05% of (Reading + Range)

Power Read Back

Range (5 Digital): 6000W

Accuracy: ± 0.06% of (Reading + Range)

General

Typical Short Resistance: 0Ω

Maximum Short Current: 420A

Load ON Voltage: 0.4~100V

Load OFF Voltage: 0~100V

Power Consumption: 550VA

Dimension (HxWxD): 177mm x 440mm x 745mm

Weight: 29kg

Temperature: 0~40℃

Safety & EMC: CE

Option card: GPIB, RS232, USB, LAN are option, prices are same as 331XF

Datasheet

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts