For full functionality of this site it is necessary to enable JavaScript.
EMINKH.COM
0
Product image

BAUR PHG 80 TD PD VLF Diagnostics System (0 – 57 kVrms)

ModelPHG 80 TD PD
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Partial discharge testing PHG 80 TD PD

VLF truesinus®: 0 – 57 kVrms

Theoretical measurement range: 10 – 12,800 m (at v/2 = 80 m/μs)

Velocity of propagation (v/2), adjustable: 50 – 120 m/μs

Sampling rate: 100 MSamples/s (10 ns)

PD measurement range: 1 pC – 100 nC

Accuracy: Approx. 1% of cable length

Resolution: 0.1 pC / 0.1 m

Calibrator

Electrical charge (pulses)

CAL1B: 0.1 / 0.2 / 0.5 / 1 / 2 / 5 / 10 nC

CAL1E: 0.5 / 1 / 2 / 5 / 10 / 20 / 50 nC

Power supply: 9 V block battery, DIN/IEC 6F22

BAUR Software 4

Information about the BAUR Software 4 and the system requirements can be found in the data sheet for BAUR Software 4 cable testing and diagnostics.

General

Display: TFT monitor acc. to quotation

Power supply:

200 – 260 V, 50/60 Hz

Option: 100 – 140 V, 50/60 Hz with auto transformer

Max. power consumption: 3,500 VA

Ambient temperature (HV generator): -20°C to +55°C

Storage temperature (HV generator): -30°C to +70°C

Relative humidity: > 90%, non-condensing

Dimensions (W x H x D) (HV generator): Approx. 483 x 623 x 775 mm

Weight

HV generator: Approx. 160 kg

Total: From 250 kg (depending upon equipment)

Safety and EMC: CE-compliant in accordance with Low Voltage Directive (2014/35/EU), EMC Directive (2014/30/EU), EN 60068-2-ff Environmental testing

Standard delivery

The standard delivery depends on the quotation.

Datasheet 

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts