For full functionality of this site it is necessary to enable JavaScript.
EMINKH.COM
0
Product image

FLUKE FLUKE-572-2 High-Temperature Infrared Thermometer (-30 °C đến 900 °C)

In Stock: 3 Unit
ModelFLUKE-572-2
P/N4328074
OriginChina
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

IR range :-30 °C to 900 °C (-22 °F to 1652 °F)

IR accuracy:

≥ 0°C: ± 1°C or ± 1 %

≥-10 °C to <0 c:

<-10°C: ±3 °C

IR repeatability: ±0.5 %

Display resolution: 0.1 °C / 0.1 °F

Distance Spot: 60:1

Minimum spot size: 19 mm

Laser sighting Offset dual laser, output <1 mw

Spectral response: 8 μm to 14 μm

Response time (95 %): <500 ms

Emissivity: 0.10 to 1.00

K-type thermocouple:-270 °C to 1372 °C (-454 °F to 2501 °F)

Hi/Low alarms: Audible and two-color visual

Min/Max/Avg/Dif: Yes

Switchable celsius and fahrenheit: Yes

Backlight: Two levels, normal and extra bright for darker environments

Trigger lock: Yes

Data storage: 99 points

Display: Dot matrix 98 x 96 pixels with function menus

Communication: USB 2.0

Weight: 0.322 kg (0.7099 lb)

Power: 2 AA batteries

Includes: K-type thermocouple bead probe, Durable hard case, USB 2.0 computer interface cable


Infrared Measurements
Infrared temperature range -30 °C to 900 °C (-22 °F to 1652 °F)
IR accuracy (calibration geometry with ambient temperature 23 °C ± 2 °C) ≥ 0°C: ± 1°C or ± 1 % of the reading, whichever is greater
≥-10 °C to <0 c:="" 2="" c="" br=""> <-10°C: ±3 °C

≥32°F: ± 2°F or ± 1% of the reading, whichever is greater
≥14 °F to <32 f:="" 4="" f="" br=""> <14 f:="" 6="" f="" td="">
IR repeatability ±0.5 % of reading or ±0.5 °C (±1 °F), whichever is greater
Display resolution 0.1 °C / 0.1 °F
Distance: Spot 60:1 (calculated at 90 % energy)
Minimum spot size 19 mm
Laser sighting Offset dual laser, output <1 mw="" td="">
Spectral response 8 μm to 14 μm
Response time (95 %) <500 ms="" td="">
Emissivity Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials

 

Contact Measurements
K-type thermocouple input temperature range -270 °C to 1372 °C (-454 °F to 2501 °F)
K-type thermocouple input accuracy (with ambient temperature 23 °C ± 2 °C) <-40 c:="" 1="" c="" 0="" 2="" 1="" c="" td="">
≥-40 °C: ±1 % or 1 °C, whichever is greater
<-40 f:="" 2="" f="" 0="" 2="" 1="" f="" td="">
≥-40 °F: ±1 % or 2 °F, whichever is greater
K-type thermocouple 0.1 °C/0.1 °F
K-type thermocouple repeatability ±0.5 % of reading or ±0.5 °C (±1 °F), whichever is greater

 

Measurement Options
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Switchable celsius and fahrenheit Yes
Backlight Two levels, normal and extra bright for darker environments
Probe input K-type thermocouple simultaneous display of probe and IR temperature
Trigger lock Yes
Data storage 99 points
Display Dot matrix 98 x 96 pixels with function menus
Communication USB 2.0

 

K-Type Thermocouple Specifications
Measurement range (bead probe) -40 °C to 260 °C (-40 °F to 500 °F)
Accuracy ±1.1 °C (±2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F). Typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)
Cable length 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination

 

General Specifications
Safety and compliance IEC 60825-1
FDA Laser Class II
IEC 61326-1
CE Complaint
CMC # 01120009
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage temperature -20 °C to 60 °C (-4 °F to 140 °F)
Relative humidity 10 % to 90 % RH non-condensing up to 30 °C (86 °F)
Operating altitude 2000 meters above mean sea level
Weight 0.322 kg (0.7099 lb)
Power 2 AA batteries
Battery life 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle (thermometer continuously on)

572-2 Infrared Thermometer Data Sheet »

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support