DC Voltage (Autorange): 200.0mV/ 2.000V/ 20.00V/ 200.0V/ 1000V; ±(1.0%rdg + 3dgt); 10MΩ; 1000VDC/ACrms

AC Voltage (Autorange):

200.0mV; ±(1.5%rdg + 15dgt); ±(1.0%rdg + 4dgt); 10MΩ; 50 ÷ 60Hz; 1000VDC/ACrms

2.000V/ 20.00V/ 200.0V/ 1000V; ±(1.0%rdg + 4dgt); 10MΩ; 50 ÷ 60Hz; 1000VDC/ACrms

AC Current:

2.000A; ±(2.5%rdg + 10dgt); 50 ÷ 60Hz; 600Arms

20.00A/ 200.0A; ±(2.5%rdg + 4dgt); 50 ÷ 60Hz; 600Arms

600.0A; ±(3.0%rdg + 4dgt); 50 ÷ 60Hz; 600Arms

Resistance and Continuity test (Autorange):

200.0Ω/ 2.000kΩ/ 20.00kΩ/ 200.0kΩ/ 2.000MΩ; ±(1.0%rdg + 5dgt); ≤100Ω; 600VDC/ACrms

20.00MΩ; ±(2.0%rdg + 10dgt); ≤100Ω; 600VDC/ACrms

Diode test:0.3mA typical; 1.5VDC

Size: 215(L) x 74(La) x 43(H)mm

Weight (including battery): 285g

Max conductor size: 30mm

Display: 3½ LCD (max 2000 counts), decimal point, unit symbol indication and backlight

Sample rate: 2 times/sec

Conversion mode: mean value

Battery type: 1 battery 9V NEDA 1604 IEC 6F22 JIS 006P.

Auto power OFF: about 15 minutes of idleness


Accessories:

Carrying bag HT9012

Pair of Lead YAAMK0000HT0

Batteries and user manual