Voltage: 0~1500V
Current: -65A~65A
Power: -42kW~42kW
CV Mode
Range: 0~1500V
Setting Resolution: 10mV
Setting Accuracy(23±5°C): ≤0.02%+0.02%F.S.
Voltage Ripple (20Hz~20MHz): ≤3Vp-p; ≤0.4Vrms
CC Mode
Range: -65A~65A
Setting Resolution: 0.11mA
Setting Accuracy(23±5°C): ≤0.1%+0.1%F.S.
Current Ripple (20Hz~20MHz): ≤1.4Ap-p; ≤200mArms
CP Mode
Range: -42kW~42kW
Setting Resolution: 0.1W
Setting Accuracy(23±5°C): 0.1%+0.1%F.S.
Voltage Measurement
Range: 0~1500V
Readback Resolution: 10mV
Readback Accuracy(23±5°C): ≤0.02%+0.02%F.S.
Temperature Coefficient: ≤15ppm/°C
Current Measurement
Range: -65A~65A
Readback Resolution: 0.1mA
Readback Accuracy(23±5°C):≤0.1%+0.1%F.S.
Temperature Coefficient: ≤30ppm/°C
Line Regulation
Voltage: <0.01%F.S.
Current: <0.02%F.S.
Load Regulation
Voltage: <0.01%F.S.
Current: <0.05%F.S.