Equip with metal rods: Φ5*1, Φ7*1, Φ9*1, Φ10*1, Φ12*1,
Φ14*1, Φ16*1, Φ18*1, Φ20*1, Φ22*1, Φ25*1, Φ30*1, Φ32*1, Φ40*1
Equip with hook weights: 20N*1, 40N*1, 50N*1, 60N*1,
through-hole weights: 10N*1, 20N*1
Disk diameter: 250mm
Diameter of test rod (mm) | Metal glands (N.m) | moulded
plastic glands (N.m)
Up to 7 | 6.25 | 2.5
7~14 | 6.25 | 3.75
14~20 | 7.5 | 5
Over 20 | 10 | 7.5
The screwed glands torque test apparatus is designed according to IEC60598-1 clause 4.1.2.5, IEC60884-1, GB2099.1 clause 24.6 and GB7000.1 clause 4.12.5. It is applied to test the screwed glands against the torque strength. Screwed glands shall be fitted with a cylindrical metal rod having a diameter equal to the nearest whole number of millimeters below the internal diameter of the packing. The glands shall then be tightened by means of a suitable spanner, apply a proper force at a distance of 250 mm from the axis of the screwed gland on the spanner for 1 minute, the luminaire and the glands shall show no damage.