For full functionality of this site it is necessary to enable JavaScript.
EMINKH.COM
0

Picotest P2105A probe: Outstanding features and practical applications

04/27/2023 08:56:58

The Picotest P2105A probe is a high-quality measuring device, designed to measure electronic parameters in a wide range of practical applications. With high accuracy and resolution, the P2105A probe can measure parameters such as voltage, current, impedance and capacitance.

The Picotest P2105A probe is a high quality measuring instrument designed to measure electronic parameters in a wide range of practical applications. With high accuracy and resolution, the P2105A probe can measure parameters such as voltage, current, impedance and capacitance. To better understand the features and uses of this electronic component, please refer to this article with EMIN!

Đầu dò Picotest P2105A

Picotest P2105A probe - probe ‘‘Browser’’’

The Picotest P2105A probe is a 50 ohm single-port line TDR probe designed specifically for TDT/TDR applications. Featuring a 1-port reflector method, the P2105A supports a wide variety of measurements including impedance, ripple, noise, PCB power rails, VRM, and clock vibration. With its low inductance, this probe minimizes space constraints on dense PCBs and eliminates the need for additional SMA connections or other test points.


The P2105A is known as the 'browser' probe because of its ability to move easily and quickly from one point to another simply by resetting the probe points. This simplifies repeatable measurements, especially when there are multiple rails to evaluate and insufficient time or PCB iterations to provide a checkpoint implementation for each rail.


The P2105A comes in a variety of fixed pin steps (20, 31, 40, 50, 60, 70 or 100 mil spacing with 1X attenuation; GSG SMA and custom pitch are also available), making it compatible with all all 50 ohm devices, including the J2154A PerfectPulse TDR, vector network analyzer (VNA), oscilloscope and spectrum analyzer. The P2105A probe is also designed to work with a traditional single-ended TDR setup.

Outstanding features of the Picotest P2105A . probe

Đầu dò Picotest P2105A

  • 15GHz single-head precision high-bandwidth probe for all Time Domain Reflectometry (TDR) applications

  • Compatible with Picotest J2154A PerfectPulse TDR

  • Fixed throws available: 20, 31, 40, 50, 60, 70, 100 million or GSG SMA

  • Custom pitch spacing available

  • Compatible with all 50 ohm . instruments

  • Spring feet for easy landing

  • Short pins and integrated but detachable PDN cable for low coupling and optimal shielding

  • Handheld browser style for easy exploration and iteration; Handle design fits most probe holders

  • Slim low profile housing for comfort and visibility

Applications

  • Low Cost PCB Coupon Tester - Characteristic Impedance PCB Trace

  • Measure voltage ripple and noise

  • Measure PCB trace length, characteristic impedance and dielectric constant

  • Locate and detect impedance mismatches

  • Measure parasitic values ​​of inductance and capacitance such as link wires, vias and ESL

  • Measure PCB trace path rise/fall time and over/under correction

  • Support loss-of-trace and cable models

Conclude:

This is a convenient and precise probe product for PCB TDR applications. With easy movement between test points and low inductance, the P2105A minimizes space constraints on dense PCBs and optimizes PCB rail analysis and evaluation. This product is also compatible with a variety of measuring instruments and is designed to work with a traditional single-ended TDR setup, saving time and improving measurement efficiency. All in all, the Picotest P2105A Probe is a product worth considering for use in TDR applications on PCBs.


Above are all the shares of the ad about the Picotest P2105A probe, hope that this article will help you in your work and how to use this electronic component. If you have any questions please feel free to contact Fanpage or Website to get it resolved as soon as possible


Related News

Does thermal shock cause damage to electronic components?
07/22/2026 10:40:49

An electronic component may operate stably under constant temperature conditions yet fail after repeated rapid transitions between hot and cold. The issue typically stems not from a specific temperature level, but rather from the rate of temperature change and the number of hot-cold cycles

The rigorous standards behind a multi-million-dollar MRI suite
07/21/2026 14:54:01

An MRI system may be correctly installed and fully connected to the power supply, yet still encounter issues if the surrounding environment fails to meet technical specifications. Electromagnetic interference, RF shielding, power quality, grounding, temperature, humidity, and particulate levels are all factors that may require assessment, depending on the facility's design and the manufacturer's requirements.

Sinusoidal and Random Vibration: A Test Setup Guide for Industrial Engineers
07/21/2026 10:30:38

During the operation of industrial machinery or the transportation of goods, persistent mechanical vibrations inevitably occur; these are a primary cause of material fatigue, loosened connections, and cracking in printed circuit boards (PCBs). To ensure product integrity before delivery to customers, R&D and QA/QC engineers must simulate these dynamic forces using vibration test systems.

Capacities of laboratory centrifuge tubes
07/20/2026 13:55:40

Tubes with capacities of 0.2 ml, 1.5 ml, 15 ml, or 50 ml are commonly found in laboratories, yet each type is associated with specific sample categories and equipment configurations. DNA and RNA samples typically require small-volume microtubes; blood and cell samples often utilize 5 ml or 15 ml tubes; while large-volume processing workflows may require tubes of 50 ml, 100 ml, or greater capacity

How Much Does Atmospheric Pressure Need to Drop Before It Rains ?
07/20/2026 10:11:04

A barometric pressure meter (barometer) often detects changes in weather conditions before rainfall begins. As atmospheric pressure falls, the structure of the surrounding air mass is also changing. However, there is no fixed pressure threshold that guarantees rain will occur.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts