Carbon Dioxide Sensor Type: Solid-state Infrared

Accuracy - Carbon Dioxide: Accuracy (for 0-50%, 0-100% range): ± 1% of reading, or ± 0.2% (whichever is greater), Accuracy (for 0-10%, 0-20% range): ± 1% of reading or ± 0.1% CO2 (whichever is greater, Accuracy (for 0-2000

CO2 Minimum Detection Limit: 0.1% (0-50% and 0-100% ranges), 0.01% (0-2.5%, 0-10% and 0-20% ranges), 10 ppm (0-5000ppm)

CO2 Calibration Controls: Potentiometer SPAN adjustment for CO2.

CO2 Calibration Frequency: Every 12 months; calibration gas recommended.

Expected Lifetime (oxygen): 4-5 years

Oxygen Range: 0.0 to 100%

Oxygen Sensitivity: 0.1% (or optional 0.01%)

O2 Resolution: 0.1% O2 (optional .01%)

Analog Output: 0-1Vdc linear proportional to concentration

Accuracy: : +/- 1% of reading; +/- 0.1% absolute below 10.0%

Drift: less than 0.4% per year

Oxygen Sensor Type: Proprietary Electrochemical

Response Time: 25 seconds to T95

O2 Sensor Lifetime: 4-5 Years

O2 Sensor Body: ABS Resin

Sample Connection: Front panel fitting with luer connection for disposable filter, plastic splitter; 1/16 to 1/8 ID tubing; (optional) Swaglok inlet

Sample Method: Pump (Optional)

Sample Pump: (Optional) Miniature diaphragm type with ~5cc/sec flow

Pump Timing: (Optional) 2-mode pump switch (timed, or continuous); (optional) cycling pump with on/off timer

Minimum Sample Required: 20cc

Sampling Assembly: Inlet fitting

Oxygen Calibration Controls: SPAN adjustment, zero adjustment

Instrument Calibration: Calibrates with room air; coarse SPAN adjustment on back; fine span adjustment on side; ZERO adjustment on side (calibration gas recommended for CO2)

Exhaust port: Vents to air OR tube outlet for recirculation to closed systems

Power Supply: 100-240V (50-60Hz) Charger included, with US or international interchangeable plug adapter (upon request)

Backup Power: Optional 12V internal battery pack

Battery Operation: Optional

Input Voltage: 100-240V, 50-60Hz

Battery Life: 8-12 hours before recharging

Measures: O2, CO2: O2, CO2

Form Factor: Benchtop

Size: 9.8W x 4H x 10L in. (249 x 102 x 254 mm)

Weight: 9.8 lb. (4.4 Kg)

Standards: CE, RoHS

Included Consumables: Plastic syringes for sample collection, 5 spare internal moisture blocking filters

Options: Battery, 0.01% resolution for O2

Included Documentation: Owners manual (includes operating instructions with detailed calibration instructions, calibration certficate, precautions), NIST calibration certificate

Origin of Goods: Our products are manufactured in the U.S.A.

Products by Gas: Oxygen and CO2

Products by Applications: Gas Flow / Process Analyzers

Datasheet

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts