Chamber Specifications
Temperature Range:
-100°C to 200°C
Extended low temperature options down to: -185°C
Extended high temperature options up to: +500°C
Temperature Transition Rate:
Heating: 18°C to 30°C/min. (Voltage/Current dependent)
Cooling: 20°C~80°C/min.
Workspace Dimensions: 13.5”H x 19.5”W x 13.5”D (34.3cm x 49.5cm x 34.3cm)
Internal Volume: 2.1 ft3 (59.0 liters)
External Dimensions: 18.0”H x 23.5”W x 27.7”D (45.7cm x 59.7cm x 70.4cm)
Extended Temp. Dims: 21.5”H x 27.5”W x 31.9”D (54.6cm x 69.9cm x 81.0cm); Excludes latches, hinges, and controller
Mounting Style: Benchtop/Optional: Floor Standing or Rack Mounting
Coolant Type: LN2 (LCO2 optional reduced low end temp)
Power Requirements (can be configured for CE):
100-120V / 50HZ-60HZ / 1PH / 20-30A
200-240V / 50HZ-60HZ / 1PH / 13-30A
Options:
• Delivery Hoses: Vacuum Jacketed; others (see left)
• Independent Failsafe Module (IFM) (on Controller, see Page 2) with Redundant Solenoid Valves (RSV) Shuts off coolant to prevent runaway cold condition
• Shelves / Interior Lights / Windows / Pull-off Doors
• Additional Apertures / Notches
• Dry Nitrogen Purge for Moisture Control
• Dewar Accessories: Distribution Manifolds, Pressure Regulators
• Benchtop, Rack Mount, and Castered Stand Configurations
Controller Specifications
Temperature Measurement:
Range: -210°C to 680°C
Accuracy: ±1.0°C
Resolution: 0.1°C full scale
User Interface: 5.7” color touch-screen with temperature graphing and charting
Control Safety: Independent Fail-Safe Module (IFM) (optional) high and low temperature limits
Compliance: CE / RoHS / Designed to meet UL 61010
Diagnostics: Controller, chiller, & blower runtime hours; Valve activation counts; Controller enclosure temperature; System performance log
Operating Environment:Temperature: 10°C to 50°C; Humidity: 10% to 50%
Temperature Inputs: RTD (500 Ohm/2Wire) (100 Ohm/3 Wire); Thermocouple (type K)
Control Algorithms: Primary loop PID, Dual loop, settable DUT control
Communication Interfaces: Ethernet 10/100 / Telnet / HTML Web Server / USB-2.0 ; Optional: RS232 and IEEE-488 GPIB
Power Requirements: Voltage: 100 to 250 VAC; Frequency: 50/60 Hz; Current: up to 30A (application based)
Physical Dimensions: (TS1-4) 8.5”H x 6”W x 11.6”D (21.6cm x 15.2cm x 29.5cm); (TS5-8) 8.5”H x 8.0”W x 11.6”D (21.6cm x 20.3cm x 29.5cm)
Program Compatibility: Supports Sigma C, CC3, CC3.5, C4, and C5 functionality & command set
TS5-TS8 Options: Purge Set Point, Flow Meter, ON/OFF Solenoid Valve