For full functionality of this site it is necessary to enable JavaScript.
EMINKH.COM
0
Product image

UNI-T UT625B Low Resistance Ohmmeter (0.1uΩ~2000mΩ, 200A)

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Current  (customizable)/  Range/ Resolution/ Accuracy

200A /0.1uΩ~1999.9uΩ/ 0.1uΩ /±(0.4%rdg+0.04%FS) / 

100A/ -/ -

100A/ 2.000mΩ~9.999mΩ/ 0.001mΩ/ ±(0.4%rdg+0.04%FS)

50A/ 10.00mΩ~99.99mΩ/ 0.01mΩ/ ±(0.4%rdg+0.04%FS)  

5A/ 100.0mΩ~499.9mΩ/ 0.1mΩ/ ±(0.4%rdg+0.6%FS)

5A/ 500mΩ~2000mΩ/ 1mΩ/ ±(0.4%rdg+0.6%FS)

Functions

To test the contact resistance of low/medium/high-voltage circuit breakers;

To test bus connections and other high-current connection points.

Resistance measurement: 0.1uΩ~2000mΩ: 0.1uΩ

Test method:
Four-wire Kelvin test;

Separation of current and voltage electrodes eliminates internal wiring impedance and contact resistance for more accurate measurements;

Minimizes measurement errors to achieve high-precision results when measuring low-resistance components.

Noise suppression: At 100 mV differential pressure, the noise frequency of the test lead is 50-60 Hz.

Stepping test current:

5A~ 200A DC ;

Stepping current:5A or 10A 

Test time: 10S、20S、30S、60S, stepping time: 1s.

Test duration: The maximum continuous testing time for a single run is 60 seconds.  

Resistance value comparison:

Pre-set value: 0.000~9999.9mΩ

Compare measured and set resistance values, automatically display “PASS” or “FAIL”

Over range indication:
Low Limit Alert: When the loop resistance measurement is low limit, the measurement interface will display “LO”;

Over-limit indication: when the loop resistance measurement exceeds the limit, the measurement interface will display “OL”;

Self-inspection:
Yes, Self-calibration via standard accessory “shunt” to verify measurement accuracy and ensure reliable data.

UT625B: 375μΩ

Open circuit voltage: 

UT625B  (voltage: 10V DC)

Overheating protection:

Output power: Measurement power ≤ 250W

Display: 7 inch color LCD

Printer: Built-in thermal printer

Input power supply: AC 198V~242V(50/60Hz)

Data Communication:
Supports PC connection (via USB cable).

Real-time analysis;

Historical data review;

Excel report generation.

Data storage: 200 sets; auto/manual save, Circular save

Backlight: 5 levels adjustable backlight

Low battery indication: ✔

Working environment:  -20°C~+50°C ; <85% R.H., no condensation

Storage environment:  -30°C~+60°C ; <85% R.H., no condensation

 

 Datasheet

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support